LG Dryer Error Code nP: No Heat? Check the Power Supply

Fix soonUpdated Checked against LG USA Support

LG dryer error code nP means the dryer detects no current at its heater, which LG says normally points to the home's electrical wiring. The drum may turn but stay cold. Check the power cord is firmly in a 240V outlet, then switch the dryer's breaker off for at least 10 seconds and back on.

What to try first

Safety: Switch the breaker off before you touch the plug or reach behind the dryer. Testing the outlet, the breaker or the terminal block means live 240V wiring: leave that to a licensed electrician or a technician.

  1. 1

    Make sure the code is nP

    Read the display closely. LG lists nP, PS and PF as separate codes with different checks, and the nP steps only apply when nP is what you see.

  2. 2

    Check the plug

    Make sure the power cord is pushed firmly into a grounded outlet that matches the 240V rating on the dryer's rating plate. A plug that has worked loose when the dryer was pushed back is easy to miss.

  3. 3

    Reset the dryer's breaker

    At the home's main panel, find the dryer's breaker and switch it fully off. Leave it off for at least 10 seconds, which LG says clears a power surge inside the breaker, then switch it back on.

Most likely causes of nP

  1. 1. Half of the dryer's double breaker has tripped (most common)

    The drum turns and the lights work, but the load never warms up, and the breaker does not look tripped at a glance.

  2. 2. A loose or wrongly fitted power cord (common)

    The dryer was moved, delivered or installed recently, or the plug sits loosely in the wall outlet.

  3. 3. An outlet or house circuit that does not supply the right voltage (common)

    nP comes back after the breaker reset, even though the breaker looks fine and other appliances in the house work.

  4. 4. A fault inside the dryer (less common)

    An electrician confirms the outlet supplies the correct voltage, yet the dryer still shows nP and does not heat.

When to call a pro

  • nP comes back after the breaker reset. LG says the outlet may then need a licensed electrician to confirm the dryer is getting the correct voltage.
  • The dryer was installed recently and the cord or outlet may be at fault. LG Canada suggests having the installer check both.
  • An electrician confirms the outlet is fine and the dryer still does not heat. LG says the unit then needs a repair service.
  • You smell gas near a gas dryer. Leave the gas side to a qualified technician or the gas utility.

What a nP repair costs

$70–$130

HomeGuide's 2026 national minimum service fee, which covers the first hour of a visit; the plug check and breaker reset cost nothing. LG ties nP to the home's wiring, and HomeGuide prices no breaker, outlet or electrician work, so no part figure is used. LG names no failed dryer part for nP.

Source

Why an LG dryer with nP still runs but won't heat

LG's error code list says an nP code means no current is being detected at the heater, and that this normally points to a problem with the electrical wiring in the home. So nP is about the power coming in, and the dryer is reporting it rather than causing it.

That explains the odd symptom people search for: the drum turns, the panel lights up, and the clothes stay damp. LG's own last step for nP is framed around heat: if the dryer is still not heating after the cord, breaker and outlet checks, it needs a repair service.

The half-tripped breaker people miss

LG asks for a 240V outlet, and that circuit runs through a two-part breaker. In an AppliancePartsPros forum thread, the owner of an electric LG dryer saw nP and a dryer that ran without heat. Because the breaker had not popped and nothing else in the house was affected, they doubted the house wiring was to blame.

The reply in that thread was that half of the 240V breaker had probably popped, and that a weak breaker may need replacing. That fits LG's own advice to switch the breaker fully off for at least 10 seconds rather than just checking whether it looks tripped.

nP, PS and PF: three power codes on LG dryers

LG lists three codes that sound alike. nP is no current at the heater. PS means improper voltage in the power cord, which LG says can come from the white and red wires being swapped on the dryer's terminal block. PF usually shows after a power outage and clears with LG's power reset.

The PF reset is the one people find when they search for how to reset an LG dryer: unplug it or switch off the breaker, hold Start/Pause for 5 seconds with the power off, then restore power. For nP, LG's steps center on the breaker and the outlet instead, because the fault sits in the supply.

Can a gas LG dryer show nP?

LG's nP entry talks about a 240V outlet and the heater, which describes an electric dryer. LG does not single out gas models for nP. EasyBear, a repair company, writes that on LG gas dryers nP means no power is reaching the gas valve, so the drum tumbles without heat. If you have a gas dryer, do not work on the gas line yourself; that check belongs to a qualified technician.

What a technician will check

  • The voltage at the dryer outlet, tested across both hot legs and to neutral, to see if one half of the 240V supply is missing.
  • The double-pole breaker itself, which may need replacing if one half has weakened.
  • The power cord connections at the dryer's terminal block, including whether the cord is wired correctly for a 3-wire or 4-wire outlet.
  • The heater circuit inside the dryer, checked only once the house supply is proven good.

What fixed it for other readers

No reader fixes yet. If you cleared nP, tell others what worked.

Reader fixes are shared by visitors and checked for safety, not tested by us.

Did you clear nP? Tell the next person what worked.

We publish your first name or initial, the month, and your fix. Nothing else.

Questions people ask about LG nP

How do you reset an LG electric dryer?

LG's general reset is to unplug the dryer or switch off its breaker, hold Start/Pause for 5 seconds while it has no power, then restore power. For nP, the reset that matters is at the breaker panel: switch the dryer's breaker off for at least 10 seconds, then back on.

Is there a reset button for the nP code?

No. LG's nP steps do not use a button on the dryer's control panel. The reset happens at the home's breaker panel, and if the code returns after that, LG points to the outlet and then to a repair service.

Is nP the same as the Flow Sense error on an LG dryer?

No. Flow Sense warnings such as d80, d90 and d95 mean the exhaust vent is restricted, and the fix is cleaning the lint filter and vent path. nP is a power code about current reaching the heater, and LG's nP steps cover the cord, breaker and outlet rather than the vent.

Can a bad sensor cause nP?

LG does not name a sensor for nP. In the AppliancePartsPros thread, the dryer's diagnostics once showed an HS code as well, which the owner read as a possible humidity sensor problem. That is a separate code; nP itself still points to the power supply first.

Sources